Search

Search Criteria

 
 
 
 

Products meeting the search criteria

Sort By:  
Used in weighing applications for Trucks, vehicles, Transport Vehicles, and heavyweight products-based Scales. It is placed in between the civil structure and the mechanical structure. The weight of a vehicle is measured by a converted signal coming out from its transducer.
৳0.00  Inc Tax
Used in weighing applications for Trucks, vehicles, Transport Vehicles, and heavyweight products-based Scales. It is placed in between the civil structure and the mechanical structure. The weight of a vehicle is measured by a converted signal coming out from its transducer.
৳0.00  Inc Tax
Used in Single Point Platform, Automated servo belt system, PLC Application
৳0.00  Inc Tax
HM9B Loadcell (Analog HM9B)
Short Description:
Nickel-plated alloy steel IP68 dual shear beam
High accuracy
Suitable for trucks, tracks, hoppers and other electronic weighing devices
Current calibrated (sc-option)
Manufacturer:
Zemic Europe. (B.V Netherland)
Origin:
Assembled in China
Available Capacity:
Capacity Accuracy Full Article Description
10 Ton C3 HM9B-C3-10t-12B-2-FH
20 Ton C3 HM9B-C3-20t-12B-2-FH
25 Ton C3 HM9B-C3-25t-20B(-SC) -2-FH
30 Ton C3 HM9B-C3-30t-20B(-SC) -2-FH
40 Ton C3 HM9B-C3-40t-16B-2-FH
50 Ton C3 HM9B-C3-50t-16B-2-FH
Technical Specifications HM9B
Accuracy Class OIML R60 C3
Output Sensitivity ( FS ) mV/V 2.0 ± 0.002
Maximum Capacity ( Emax ) kg 10, 20, 25 30, 40, 50
Max. Number of Load Cell Intervals nLC 3000
Ratio of min. LC Verification Interval Y = Emax / vmin 15000, 7500
Combined Error %FS ≤± 0.02
Creep Error (30 minutes) %FS ≤± 0.02
Temperature Effect on Zero (ZTC) %FS/10°C ≤± 0.02
Temperature Effect on Sensitivity (STC) %FS/10°C ≤± 0.02
Zero Balance %FS ≤± 1.5
Safe Overload %FS 150
Ultimate Overload %FS 300
Excitation, Recommended Voltage V 5 ~ 12
Excitation, Maximum Voltage V 18
Input Resistance Ω 700 ± 7
Output Resistance Ω 703 ± 4
Insulation Resistance (50V) ≥5000
Compensated Temperature °C -10 ~ 40
Operating Temperature °C -35 ~ 65
Storage Temperature °C -40 ~ 70
Load Cell Weight kg 10t: 15 20t – 40t: ~17 50t: 25
Element Material Nickel plated alloy steel
Ingress Protection (acc. to EN 60529) IP68
Recommended Torque on Fixation Bolts Nm 1100
ATEX Classification (optional) II1G Ex ia II1C T4 II1D Ex iaD 20 T73°C II3G Ex nL IIC T4
Wiring:
Cable type: Shielded, 4 conductor cable, conductor AWG 24
Cable diameter: Ø 5.5mm
Cable length: 16m (standard), 12m & 20m lengths also available
Cable jacket: PVC Shield not connected to the element
Wiring Instruction:
Input(Positive) - Red
Input (Negative) - Black
Output(Positive) - Green
Output(Negative) - White
Shield - Gray
Used in weighing applications for Trucks, vehicles, Transport Vehicles, and heavyweight products-based Scales. It is placed in between the civil structure and the mechanical structure. The weight of a vehicle is measured by a converted signal coming out from its transducer.
৳0.00  Inc Tax
HM9B Loadcell (Digital HM9B)
Short Description:
Nickel-plated alloy steel IP68 dual shear beam
High accuracy
Suitable for trucks, tracks, hoppers and other electronic weighing devices
Current calibrated (sc-option)
Manufacturer:
Zemic Europe. (B.V Netherland)
Origin:
Assembled in China
Available Capacity:
Capacity Accuracy Full Article Description
10 Ton C3 HM9B-C3-10t-12B-2-FH
20 Ton C3 HM9B-C3-20t-12B-2-FH
25 Ton C3 HM9B-C3-25t-20B(-SC) -2-FH
30 Ton C3 HM9B-C3-30t-20B(-SC) -2-FH
40 Ton C3 HM9B-C3-40t-16B-2-FH
50 Ton C3 HM9B-C3-50t-16B-2-FH
Technical Specifications HM9B
Accuracy Class OIML R60 C3
Output Sensitivity ( FS ) mV/V 2.0 ± 0.002
Maximum Capacity ( Emax ) kg 10, 20, 25 30, 40, 50
Max. Number of Load Cell Intervals nLC 3000
Ratio of min. LC Verification Interval Y = Emax / vmin 15000, 7500
Combined Error %FS ≤± 0.02
Creep Error (30 minutes) %FS ≤± 0.02
Temperature Effect on Zero (ZTC) %FS/10°C ≤± 0.02
Temperature Effect on Sensitivity (STC) %FS/10°C ≤± 0.02
Zero Balance %FS ≤± 1.5
Safe Overload %FS 150
Ultimate Overload %FS 300
Excitation, Recommended Voltage V 5 ~ 12
Excitation, Maximum Voltage V 18
Input Resistance Ω 700 ± 7
Output Resistance Ω 703 ± 4
Insulation Resistance (50V) ≥5000
Compensated Temperature °C -10 ~ 40
Operating Temperature °C -35 ~ 65
Storage Temperature °C -40 ~ 70
Load Cell Weight kg 10t: 15 20t – 40t: ~17 50t: 25
Element Material Nickel plated alloy steel
Ingress Protection (acc. to EN 60529) IP68
Recommended Torque on Fixation Bolts Nm 1100
ATEX Classification (optional) II1G Ex ia II1C T4 II1D Ex iaD 20 T73°C II3G Ex nL IIC T4
Wiring:
Cable type: Shielded, 4 conductor cable, conductor AWG 24
Cable diameter: Ø 5.5mm
Cable length: 16m (standard), 12m & 20m lengths also available
Cable jacket: PVC
Shield not connected to the element
Wiring Instruction:
Input(Positive) - Red
Input (Negative) - Black
Output(Positive) - Green
Output(Negative) – White
Shield - Gray
Used in weighing applications for Trucks, vehicles, Transport Vehicles, and heavyweight products-based Scales. It is placed in between the civil structure and the mechanical structure. The weight of a vehicle is measured by a converted signal coming out from its transducer.
৳0.00  Inc Tax
H6F Load Cell (H6F)
Short Description:
Nickel plated alloy steel IP66 single point load cell
Bending beam
Suitable for belt, platform and other electronic weighing devices
Maximum platform size:
1. for 50kg-200kg: 400 x 400 mm
2. for 250kg-500kg: 600 x 800 mm
3. for 750kg-2t: 1200 x 1200 mm
Manufacturer:
Zemic Europe
Origin:
B.V Netherland
Available Models:
Capacity Accuracy Full Article Description
100kg C3 H6F-C3-100kg-3B6
150kg C3 H6F-C3-150kg-3B6
200kg C3 H6F-C3-200kg-3B6
250kg C3 H6F-C3-250kg-3B6
500kg C3 H6F-C3-500kg-3B6
750kg C3 H6F-C3-750kg-3B6
1000kg C3 H6F-C3-1000kg-3B6
2000kg C3 H6F-C3-2000kg-3B6
Technical Specifications of H6F
Accuracy Class C3
Output Sensitivity ( FS ) mV/V 2.0 ± 0.2
Maximum Capacity ( Emax ) Kg 100, 150, 200, 250, 500, 750, 1000, 2000
Max. Number of Load Cell Intervals nLC 3000
Ratio of min. LC Verification Interval Y = Emax / Vmin 7500
Combined Error %FS ≤± 0.020
Minimum dead load Of Emax 0%
Safe overload Of Emax 150 %
Ultimate overload300 % Of Emax 300 %
Zero balance Of FS < ± 1.0 %
Excitation, recommended voltage V 5 ~ 12
Excitation maximum V 18
Input Resistance Ω 384 ± 4
Output Resistance Ω 351 ± 2
Insulation Resistance ≥5000 (at 50VDC)
Compensated Temperature °C -10 ~ 40
Operating Temperature °C -35 ~ 65
Storage Temperature °C -40 ~ 70
Element Material Nickel plated alloy steel
Ingress Protection (acc. to EN 60529) IP66
Recommended Torque on Fixation Bolts Nm M12:75; M16:200
ATEX Classification (optional) II1G Ex ia II1C T4 II1D Ex iaD 20 T73°C II3G nL IIC T4
Wiring:
Shielded, 6 conductor cable
Cable diameter: Ø6.2mm
Standard cable length: 3m
Shield not connected to element
Wiring Instruction:
Input (Positive) - Red
Sense (Positive) - Brown
Output (Positive) - Blue
Output (Negative) - White
Sense (Negative) - Black
Input (Negative) - Yellow
Dimension Wise Capacity:
Dimension Capacity B B1 H H1 H2 L L1 L2 M
50-200kg 44 24 75 50 30 156 112 14 M12
250-500kg 60 36 95 70 30 146 110 11 M12
750kg-2000kg 76 46 125 95 65 176 110 24 M16
Used in Single Point Platform, Automated servo belt system, PLC Application
৳0.00  Inc Tax
Per Page      1 - 3 of 3
  • 1

About Us

GATCO-GLOBAL ASIA TRADING COMPANY was Founded in 1995. Started with Medical instruments and accessories, High precision measurement instruments, Machine programming software (HMI – Human Machine Interface ), Automatic industrial machinery, and Industrial Automation software exporting.

Contact Us